1Perform a draft test on all windows before beginning any repair. Perform this on a cold, windy day when the effect will be most pronounced. Light a stick of incense or a candle and hold it 1 inch from the window perimeter with the window closed. Deflecting smoke or a disturbed flame indicates an air infiltration site. Mark each leak location with masking tape and photograph them before beginning work.
2Replace weatherstripping on any window where the existing seal is compressed flat, cracked, or has gaps. Window weatherstripping is type-specific — foam compression seal, V-strip, or pile — and must be matched to the existing application. Remove the sash if possible to replace weatherstripping on both the sash and the frame. For casement windows, the EPDM rubber perimeter gasket is the primary seal and is typically glued into a channel; replacement requires removing the old adhesive completely before installing new material.
3Apply rope caulk or foam backer rod to large gaps around the sash perimeter as a temporary or supplemental measure. Rope caulk is a peel-and-press rope-like material available at hardware stores that can be installed without tools and removed in spring without damage. It is not a permanent solution but provides immediate draft reduction at low cost. For larger gaps, foam backer rod installed before caulking provides better fill and a better surface for the caulk to adhere to.
4Check and adjust multi-point lock compression on casement, awning, and tilt-turn windows. Close the window and observe the sash perimeter — there should be no visible gap at any point. If the sash bows away from the frame at the corners, adjust the lock keeps (the strike plates) inward to increase compression. Most keeps are adjustable with a screwdriver and can compensate for minor seal compression loss without replacing the weatherstripping.
5For persistent drafts despite weatherstripping replacement, investigate the rough opening. Remove the interior window casing on the leakiest window and inspect the gap between the window frame and the rough framing. Fill any gaps larger than 1/4 inch with low-expansion spray foam insulation. Do not use standard expanding foam, as it can bow the window frame — use specifically labeled "window and door" low-expansion foam.
6If the window glass itself is cold to the touch at the center of the pane (indicating a failed IGU or a single-pane window), contact Virginia Glass Windows at (703) 470-7867 for an assessment. Weatherstripping and caulk alone cannot compensate for a glass unit that conducts cold. A failed IGU replacement or full window upgrade to modern insulating glass is the correct solution.