ADA Entrance DoorCompliance Checker
Measure seven things. Find out whether your entrance passes.
- Pass or fail per ADA clause
- Exact citation for each
- What actually fixes each failure
Plan view — manoeuvring clearance
60 x 18 in requiredClear width
32"
32 in minimum
Opening force
8.0 lbf
Target 8.5
Closing speed
5.0 s
5 s minimum
Clauses failing
0
7 of 7 pass
Live result
Passing
7 of 7 clauses pass
Clear opening width
32" · ADA 404.2.3
Opening force
8.0 lbf · ADA 404.2.9
Closing speed
5.0 s · ADA 404.2.8
Threshold height
0.50 in, bevelled · ADA 404.2.5
Hardware height and operation
40", lever · ADA 404.2.7 / 309.4
Manoeuvring clearance
Pull side, front approach — 60 x 18 in required · ADA 404.2.4
Vision lite height
Full-lite door · ADA 404.2.11
Exterior entrance
This door passes every clause you measured
Keep the measurements. Opening force drifts as closers age, so it is worth re-checking twice a year on a busy entrance.
Clause by clause
Clear opening width
ADA 404.2.332 inches minimum, measured with the door open 90 degrees, from the face of the door to the opposite stop.
Measured: 32" — Clear opening of 32" meets the 32 inch minimum.
Opening force
ADA 404.2.95 lbf maximum for interior hinged doors. Exterior doors are not federally capped, but most jurisdictions and owners hold to 8.5 lbf.
Measured: 8.0 lbf — 8.0 lbf is within the 8.5 lbf target for this door.
Closing speed
ADA 404.2.8From 90 degrees to 12 degrees must take at least 5 seconds.
Measured: 5.0 s — Sweep from 90 to 12 degrees takes 5.0 seconds, at or above the 5 second minimum.
Threshold height
ADA 404.2.51/2 inch maximum. Anything over 1/4 inch must be bevelled at 1:2 or shallower.
Measured: 0.50 in, bevelled — At 0.50 inches with a bevel, this complies.
Hardware height and operation
ADA 404.2.7 / 309.4Operable parts between 34 and 48 inches above the floor, usable with one hand and no tight grasping, pinching or twisting of the wrist.
Measured: 40", lever — Lever, push-pull or panic hardware at 40" is inside the reach range and operable with one hand.
Manoeuvring clearance
ADA 404.2.4Depends on approach direction and whether the door has a closer and latch. A front approach to the pull side needs 18 inches of clear floor beyond the latch and 60 inches of depth.
Measured: Pull side, front approach — 60 x 18 in required — You confirmed clear floor for this approach: 60 inches of depth and 18 inches past the latch side. 60 in of depth and 18 in of clear floor past the latch jamb. This is the case most entrances are designed to.
Vision lite height
ADA 404.2.11Where a door has a vision lite, the bottom of at least one pane must be no more than 43 inches above the floor.
Measured: Full-lite door — A full-lite storefront door satisfies this automatically.
A screening aid against the 2010 ADA Standards for Accessible Design, not a legal opinion or a certified accessibility survey. The clearance figures shown assume a door with both a closer and a latch, which is the stricter column of Table 404.2.4.1 and the normal storefront case. Manoeuvring clearance has to be measured on the floor. Where a complaint has already been filed, engage a qualified accessibility professional.
Survey record
| Door type | Exterior entrance |
| Clear width | 32" |
| Opening force | 8.0 lbf |
| Closing speed | 5.0 s |
| Threshold | 0.50 in bevelled |
| Hardware | lever at 40" |
| Approach | Pull side / Front |
| Clearance required | 60 x 18 in |
| Clauses failing | 0 |
Next step
Want it verified on site?
We measure with a door pressure gauge, adjust what can be adjusted, and quote only what actually needs replacing.
Clauses failing
0
ADA screening passed on an exterior entrance
- Door
- Exterior entrance
- Clear width
- 32" — pass
- Opening force
- 8.0 lbf (limit 8.5) — pass
- Closing speed
- 5.0 s — pass
- Threshold
- 0.50 in bevelled — pass
- Hardware
- lever at 40"
- Approach
- Pull side, front approach
- Clearance required
- 60 in deep x 18 in past the latch
- Clearance on site
- Clear
- Result
- Passes every clause checked
- Failing clauses
- None
- Remediation
- None required
- Location
- Fairfax / Loudoun / PW
Text it to us
Opens your messages app, already written
Email it to us
Opens your mail app with the full spec
Call and read it out
(703) 470-7867 · 24/7 Emergency Service
Opening force is the clause that quietly fails
Almost every accessibility problem we find on a storefront entrance is the same one, and it is not the width or the threshold. It is opening force. Doors are commissioned at a reasonable setting and then drift. Somebody speeds the closer up because it was being held open. A pivot wears and the door starts to bind. Seasonal stack pressure in a tall lobby adds several pounds on its own. Nobody re-measures, because nothing looks broken.
The fix is usually an adjustment. Closers have separate valves for sweep speed, latch speed and back-check, plus a spring size setting on most models. A technician with a pressure gauge can walk a door from fifteen pounds down to eight in about twenty minutes. What you cannot do is turn it down so far that the door stops latching — that is the point where a power operator becomes the honest answer rather than an upsell.
The clearance nobody measures
Manoeuvring clearance is the second most common finding and the hardest to fix after the fact, because it is a floor plan problem rather than a hardware problem. A pull-side front approach wants sixty inches of depth and eighteen inches of clear floor past the latch jamb. That is a large piece of floor, and it is exactly where a queue rail, a planter, a sandwich board or a second vestibule door tends to go. Draw it on the plan before the fit-out, not after the complaint.
Measure it, do not judge it
A door pressure gauge is inexpensive and settles the argument. Feel is unreliable — a fit adult genuinely cannot tell eight pounds from fourteen by pulling on a handle, which is exactly why the standard specifies a number instead of a description. If you manage more than a couple of properties, owning a gauge and logging every entrance twice a year is the cheapest liability control in the building.
Questions people ask
Five pounds of force for interior hinged doors. The 2010 Standards deliberately do not set a federal number for exterior doors, because wind and stack pressure make it impractical — but many jurisdictions, landlords and tenant fit-out standards adopt 8.5 pounds anyway, and an entrance that takes 15 pounds will generate complaints regardless of what the letter of the rule says. Measure it with a door pressure gauge at the pull side, not by feel.
Keep going
Other free tools that pair well with this one.
Glass Replacement Spec Builder
What glass your opening needs, drawn in elevation and section.
Open tool Rated AssembliesSecurity Glazing Selector
Match a real threat to a rated product, without over-specifying by ten times.
Open tool True 3D3D Commercial Entrance Designer
Build the entrance in 3D, swing the door, check ADA before you order.
Open tool